A review of U.S. Navy experience in the development of a shipboard gas turbine condition monitoring system (CMS) is presented. The system considered was developed for use with the 20,000 HP General Electric, LM2500 main propulsion gas turbine engines used on the Navy's DD-963 class destroyers and FFG-7 patrol frigate class ships. The initial CMS development program started with a broad range of measured gas turbine parameters and was successively reduced to a simpler system using only selected paramters useful for the marine application. A landbased test as well as an at-sea test is presented, together with a discussion of the impact such a system would have on DD 963 class engine removals. (Wassmann)


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    US Navy, LM 2500 gas turbine condition monitoring development experience


    Weitere Titelangaben:

    Entwicklungserfahrungen mit dem LM 2500 Gasturbinenzustandsueberwachungssystem der US Marine


    Beteiligte:
    Kandl, M.G. (Autor:in) / Groghan, D.A. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1980


    Format / Umfang :

    9 Seiten, 9 Bilder, 3 Tabellen, 3 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch







    LM 2500-An Aero-derivative Marine Gas Turbine

    Potesta,A.M. / Fiat Aviazione,IT | Kraftfahrwesen | 1979


    Condition monitoring in the Royal Navy

    Podmore, C. / Institute of Marine Engineers | British Library Conference Proceedings | 1994