A test program was designed to evaluate various voltage-temperature (V-T) charge curves for use in low-Earth-orbit (LEO) applications of nickel-cadmium battery cells. The trends established relating V-T level to utilizable capacity were unexpected. The trends toward lower capacity at higher V-T levels were predominant in these tests. This effect was a function of the V-T level, the temperature, and the cell history. It was attributed to changes occurring in the positive plate. The results imply that for some application, the use of even lower V-T levels may be warranted. The need to limit overcharge, especially in the early phases of missions, in underlined by test program.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Voltage-temperature charge verification testing of 34 ampere hour nickel-cadmium cells


    Weitere Titelangaben:

    Testprogramm fuer die Temperaturabhaengigkeit des Ladestroms von Nickel-Cadmium-Batterien fuer die Raumfahrttechnik


    Beteiligte:
    Timmerman, P.J. (Autor:in) / Bondeson, D.W. (Autor:in)

    Erschienen in:

    Journal of Power Sources ; 18 , 2-3 ; 197-208


    Erscheinungsdatum :

    1986


    Format / Umfang :

    12 Seiten, 10 Quellen



    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Print


    Sprache :

    Englisch