The parameters of a thyristor bridge load have the significant influence on a generator performance. By the careful design of load reactances and load conditions it is possible to decrease the harmonic of armature current and as result to decrease the total active losses and the mechanic vibrations. The decrease of a harmonic armature voltage by external inductance is more efficient than by changing parameters of a generator. In this regard it is better to design the greater magnitude of a synchronous reactance Xd and to operate with nominal output voltage. The significant increase of the reactive power of classical marine generator under thyristor operation is noted. Hence its overall efficiency is low.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Properties of the salient-pole synchronous generator GD8-1000-50 in the ships thyristor drive


    Weitere Titelangaben:

    Verhalten eines Schenkelpolsynchrongenerators GD8-1000-50 bei umrichtergesteuerten Asynchronantrieben auf Schiffen


    Beteiligte:


    Erscheinungsdatum :

    1983


    Format / Umfang :

    8 Seiten, 3 Bilder, 1 Tabelle, 6 Quellen


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch