Abstract The paper presents the results of the compressive strength, splitting tensile strength, flexural tensile strength and elastic modulus testing of high strength concrete at 28 and 56 days of maturation, depending on two factors: the portion of 2/16 mm fraction gravel aggregate and the portion of 2/16 mm fraction boiler slag. The analysis and conclusions were justified by the results of laboratory experiments and developed mathematical models describing the dependence of the selected characteristics of the material obtained from the compound composition - the portion of boiler slag and gravel aggregate in the aggregate mix, as well as the observation results of the obtained material microstructure.
The Possibility of Using Boiler Slag as Coarse Aggregate in High Strength Concrete
KSCE Journal of Civil Engineering ; 22 , 5 ; 1816-1826
12.10.2017