Abstract The results of testing a number of space-based detectors that contain PMTs or high-voltage electrodes for the noise from the microphonics that occurs in the signal path due to external mechanical action have been presented. A method for the vibration isolation of instruments aboard a spacecraft has been proposed to reduce their responsivity to vibrations.
Study of the Microphonics for Prospective Space-Based Neutron and Gamma-Ray Detectors and Methods for its Suppression
Cosmic Research ; 56 , 3 ; 208-212
2018-05-01
5 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Retro-prospective in IR optical detectors
SPIE | 2004
|Advanced Space-Based Detectors
NTIS | 2014
|Background suppression techniques in germanium detectors
NTRS | 1992
|Background Suppression Techniques in Germanium Detectors
British Library Online Contents | 1992
|