Experiments were performed to quantify the effect of contamination in the helium working gas of a typical pulse tube cryocooler operating at 60 K with 1 W of applied heating load. A quadrupole mass spectrometer with a closed ion source was used to measure the gas compositions both before and after pulse tube operation. Five tests were performed with different combinations of water, carbon dioxide, nitrogen and argon gas contaminating the helium across a range of 20 to 420 parts per million (ppm). Except for hydrogen, no other contaminants were detected in any experiment either before or after running the pulse tube. A decrease in pulse tube refrigeration performance was observed in all five tests, with asymptotic steady-state temperatures reached on a time scale of 7 to 10 days. Under a 1 W applied load condition with a constant piston stroke, the cold head temperature rise ranged from 0.6 to 2.8 K depending on contamination level. Comparisons between cryopumped and non-cryopumped vacuum chambers appeared to rule out the possibility that the contamination was external to the pulse tube. Water and carbon dioxide were the most important contaminants at the nominal operating temperature of 60 K, although there was evidence for nitrogen condensation under some conditions. Warming up of the pulse tube to room temperature tended to restore the original performance, although this improvement degraded more rapidly the second time around to the asymptotic steady-state temperature.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Gas Contamination Effects on Pulse Tube Performance


    Beteiligte:
    Ross, R. G. (Herausgeber:in) / Hall, J. L. (Autor:in) / Ross, R. G. (Autor:in)

    Erschienen in:

    Cryocoolers 10 ; Kapitel : 41 ; 343-350


    Erscheinungsdatum :

    2002-01-01


    Format / Umfang :

    8 pages




    Medientyp :

    Aufsatz/Kapitel (Buch)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch




    Gas Contamination Effects on Pulse Tube Performance

    Hall, J. L. / Ross, R. G. | NTRS | 1997


    Gas Contamination Effects on Pulse Tube Performance

    Hall, J. L. / Ross, R. G. | British Library Conference Proceedings | 1999


    Performance of a Tapered Pulse Tube

    Swift, G. W. / Allen, M. S. / Wollan, J. J. | British Library Conference Proceedings | 1999


    Performance of a Tapered Pulse Tube

    Swift, G. W. / Allen, M. S. / Wollan, J. J. | Springer Verlag | 2002


    Experiments on the Effects of Pulse Tube Geometry on PTR Performance

    Kirkconnell, C. S. / Soloski, S. C. / Price, K. D. | British Library Conference Proceedings | 1997