Abstract Modular Steel-plate Composite (SC) construction reduces the construction time and labor requirement in their implementation for nuclear plants. For an effective structural design using SC wall panel, non-slender member is preferred for a faceplate of SC wall panel to satisfy the strength limit and the serviceability limit. The existing specifications developed for SC wall panel construction suggest width-to-thickness ratios (or faceplate slenderness ratios); however, these ratios differ in various specifications. This paper recommends the slenderness ratio of faceplates in SC wall panel. The results reveal that the faceplate slenderness ratio, the ratio of b/t p , should be less than or equal to 0.907 . In addition, the maximum stud (or tie) spacing will be a useful parameter to be considered during fabrication of SC wall, for structural design and also for field applications.
Determination of Slenderness Ratio of Faceplates in Steel-Plate Composite Wall Panels
KSCE Journal of Civil Engineering ; 23 , 2 ; 691-698
17.12.2018
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Determination of Slenderness Ratio of Faceplates in Steel-Plate Composite Wall Panels
Online Contents | 2019
|Slenderness ratio distribution and load-shortening behaviors of stiffened panels
British Library Online Contents | 2012
|The bifurcation slenderness ratio of rectangular tubes
British Library Conference Proceedings | 1999
|Effect of Slenderness Ratio on Free-to-Roll Wing Aerodynamics
Online Contents | 2011
|Large-slenderness-ratio split type light skin reinforced cabin structure
Europäisches Patentamt | 2024
|