Based on the imaging features of the original image intensifier of X-ray, the light halo caused by X-ray projective halation is analyzed, the result shows the stray X-ray energy is lower than the direct X-ray energy. The screen brightness generated by the image intensifier of X-ray stimulated by the stray X-ray energy is weaker than that generated by the direct X-ray energy. In addition the projector facula reflected from the direct X-ray is focused on the central region of X-ray image intensifier, therefore a toroidal ring similar to the solar halation is formed around the projector halation. The results of the theoretical analysis and experimental discovery show this phenomenon caused by X-ray tube on X-ray image intensifier can not be eliminated and in the system of X-ray size detection composed of them the X-ray halation will reduce the detection accuracy resulting in measurement results’ deviation dispersion under given conditions. This kind of nonlinear system error can not be canceled out by the segmented modification of coefficient compensation but it can be restrained through the adjustment of correction coefficients. After the physical testing and comparison of the physical normal size the accuracy of 0.1mm of the compensated X-ray measurement results after the adjustment of correction coefficient has been reached. The results are highly reproducible and the method of the segmented coefficient compensation has been improved.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Influence by x-ray facula on dimension measurement


    Beteiligte:
    Qin, Xulei (Autor:in) / Li, Ye (Autor:in) / Duanmu, Qingduo (Autor:in) / Zhao, Peng (Autor:in)

    Kongress:

    Selected Papers from Conferences of the Photoelectronic Technology Committee of the Chinese Society of Astronautics 2014, Part I ; 2014 ; China,China


    Erschienen in:

    Erscheinungsdatum :

    04.03.2015





    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch



    Precise determination of source function of facula

    Kuz'Minykh, V.D. / Kozhevnikov, N.I. | Engineering Index Backfile | 1964


    Precise determination of the source function of a facula

    Kuzʹminych, V. D. / Koževnikov, N. I. | TIBKAT | 1964


    DIMENSION MEASUREMENT SYSTEM AND DIMENSION MEASUREMENT METHOD

    SONG YAN HOU / BABA RIKA / KODAIRA NORIMI | Europäisches Patentamt | 2021

    Freier Zugriff

    Dimension Measurement

    Kwon, Kye‐Si ;Ready, Steven | Wiley | 2014


    ELEVATOR SHAFT DIMENSION MEASUREMENT DEVICE AND ELEVATOR SHAFT DIMENSION MEASUREMENT METHOD

    KAWANISHI RYOSUKE / TSUTADA HIROYUKI / SAMBONGI KEISUKE et al. | Europäisches Patentamt | 2016

    Freier Zugriff