The jet flow at the orifice produced by a cavity-pumping device is studied in the present paper. Internal instantaneous pressure is obtained using analytical solution based on assumptions of isothermal condition and incompressible flow. An example of a venting of a cylindrical cavity with initial volume 1.59 × 10−5 m3 and orifice area 1.96 × 10−5 m2 is considered to determine the differential pressure across the orifice under the sinusoidal variation of the cavity volume. Variation of maximum pressure jump across the orifice as function of angular frequency is obtained for a given cavity volume ratio. The analytical solution of time-dependent volume of incompressible flow retains all the geometrical parameters of the synthetic jet actuator, therefore, can be employed to validate numerical solution of compressible flow under the isothermal condition.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Analytical solution for venting from a time-dependent cavity volume


    Beteiligte:
    Mehta, R C (Autor:in)


    Erscheinungsdatum :

    2007-03-01


    Format / Umfang :

    3 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch





    Launch Vehicle Cavity Venting: Modeling Concepts & Validation

    Patel, D. / American Institute of Aeronautics and Astronautics | British Library Conference Proceedings | 2013



    Urea solution venting system for vehicle

    LEE BOSUNG / HAM CHANG HO | Europäisches Patentamt | 2016

    Freier Zugriff