Based on the preliminary validation of the numerical results with an experiment, the steady results of different tip clearance size effects on the performance and tip leakage vortex of counter-rotating compressor were discussed. The predicted results showed that the stable margin and isentropic efficiency of the counter-rotating compressor decreased with increasing of the tip clearance size. Furthermore, increasing the tip clearance size had a greater negative effect on the performance of the upstream rotor than the downstream rotor. Detailed flow field analyses further demonstrated that the unstable flow occurred in the two counter-rotating rotors with greater tip clearance size. The rotor downstream was the main unstable factor which caused the counter-rotating compressor to breakdown when a smaller tip clearance size was used.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Effects of tip clearance size on the performance and tip leakage vortex in dual-rows counter-rotating compressor


    Beteiligte:
    Wang, Yangang (Autor:in) / Chen, Weixiong (Autor:in) / Wu, Canghai (Autor:in) / Ren, Siyuan (Autor:in)


    Erscheinungsdatum :

    01.09.2015


    Format / Umfang :

    13 pages




    Medientyp :

    Aufsatz (Zeitschrift)


    Format :

    Elektronische Ressource


    Sprache :

    Englisch