The thermal performance of an air-cooled turbine vane, uncoated and coated with the NASA thermal barrier coating system (yttria stabilized zirconia plus NiCrAlY bond), was experimentally studied at both transient and steady state gas conditions in a four-vane cascade. The steady state full-throttle and idle gas conditions investigated were 1550 K, 8.3 atm and 940 K, 7.1 atm, respectively. The ceramic coating reduced the temperature gradient within the airfoil and increased the time constant of the airfoil metal wall by 20 to 50 percent compared to the uncoated vane. The metal temperature of the ceramic coated airfoil also lagged changes in the gas temperature by about 0.4 seconds. In addition, the ceramic coating increased the full-throttle airfoil cooling performance which resulted in a decreased metal temperature of 200 kelvins.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Thermal Performance of a Ceramic Coated Turbine Vane under Transient Gas Conditions


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:

    Kongress:

    SAE International Congress and Exposition ; 1981



    Erscheinungsdatum :

    1981-02-01




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Thermal Performance of a Ceramic Coated Turbine Vane under Transient Gas Conditions

    Gladden,H.J. / NASA,Lewis Res.Cent.,US | Kraftfahrwesen | 1981


    Turbine vane ceramic endwall

    HAYES, C. W. / ZABIEREK, D. | AIAA | 1975


    Gas Turbine Ceramic Vane Testing

    Nessler, C. G. | SAE Technical Papers | 1974