This specification covers temperature resistant, two-component synthetic rubber compounds of the polysulfide type for sealing and repairing integral fuel tanks and fuel cell cavities, for continuous service use from -65 to +250 °F (-54 to 121 °C). This is a limited scope to remove thermal rupture testing from acceptance tests. Several formatting changes were also made to bring the specification more in-line with current standards.
Sealing Compound, Temperature Resistant, Integral Fuel Tanks and Fuel Cell Cavities, High Adhesion
28.03.2011
Aufsatz (Konferenz)
Englisch