NASA is developing three racks containing regenerative water recovery and oxygen generation systems (WRS and OGS) for deployment on the International Space Station (ISS). The major assemblies included in these racks are the Water Processor Assembly (WPA), Urine Processor Assembly (UPA), Oxygen Generation Assembly (OGA), and the Power Supply Module (PSM) supporting the OGA. The WPA and OGA are provided by Hamilton Sundstrand Space Systems International (HSSSI), Inc., while the UPA and PSM are developed in-house by the Marshall Space Flight Center (MSFC). The assemblies have completed the manufacturing phase and are in various stages of testing and integration into the flight racks. This paper summarizes the status as of April 2005 and describes some of the technical challenges encountered and lessons learned over the past year.
Status of the International Space Station Regenerative ECLSS Water Recovery and Oxygen Generation Systems
Sae Technical Papers
International Conference On Environmental Systems ; 2005
11.07.2005
Aufsatz (Konferenz)
Englisch
British Library Conference Proceedings | 2005
|Status of the Regenerative ECLSS Water Recovery and Oxygen Generation Systems
SAE Technical Papers | 2006
|Status of the Node 3 Regenerative ECLSS Water Recovery and Oxygen Generation Systems
SAE Technical Papers | 2004
|Status of the Node 3 Regenerative ECLSS Water Recovery and Oxygen Generation Systems
SAE Technical Papers | 2003
|