A single stage axial compressor was designed for 1.53:1 pressure ratio using a quasi-three dimensional design method which consists of an iterative calculation between the radial equilibrium and blade-to-blade analyses including surface boundary layers.This stage was tested in place of the production first stage of a three stage axial combined with a single stage centrifugal (3A+1C) compressor in a research gas generator. Based on stator exit traverses, the research stage reached 87.8% adiabatic efficiency and 1.65:1 pressure ratio at the design speed. The overall compressor efficiency improved significantly at high speeds in comparison with the existing 3A+1C compressor, without any obvious performance deterioration at part speed.Some aspects of the design method are discussed and the test results are presented in this paper.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Test Results from an Analytically Designed Axial Compressor Stage of 1.65:1 Pressure Ratio


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    LeBlanc, A. D. (Autor:in) / Yoshinaka, T. (Autor:in)

    Kongress:

    Turbine Powered Executive Aircraft Meeting ; 1980



    Erscheinungsdatum :

    01.04.1980




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch