A comparison of the 50th percentile male THOR-LX and Hybrid III 50th percentile male dummy lower leg was conducted via component and full scale barrier testing. In the component tests, isolated THOR-LX and Hybrid III lower legs were impacted in two different test set-ups where the tibia was impacted at three different impact points. The foot without a shoe was impacted in two different test set-ups at six different impact points. A shoe impact study was also conducted to determine the effect of a shoe on the results and to determine how many impacts a shoe can withstand at each point before properties of the shoe begin to change. For these tests, the THOR-LX and Hybrid III lower legs were repeatedly impacted at four different points on the foot with a shoe. For the full scale barrier testing, the THOR-LX or Hybrid III lower legs were attached to a belted Hybrid III 50th percentile male dummy. The dummy was positioned in a compact car for each test. Each lower extremity type was tested in a left hand side 40% offset crash at 40mph and a full frontal New Car Assessment Program (NCAP) rigid barrier test at 35 mph.This study concluded that the component testing revealed that the Achilles cable in the THOR-LX reduced the lower tibia moments about the y-axis (My) and increased the lower tibia axial forces (Fz) for dorsiflexion impacts. Upper tibia My for THOR-LX with a shoe in dorsiflexion inpacts was twice the value of My for THOR-LX without a shoe. The THOR-LX ankle reached full rotation more quickly than the Hybrid III ankle in dorsiflexion impacts contributing to the THOR-LX having higher Fz values in the lower tibia. The full scale vehicle tests showed similar performance between the THOR-LX and Hybrid III lower legs. The effects of floor pan intrusion were also evaluated.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Comparison of the THOR and Hybrid III Lower Extremities in Laboratory Testing


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Spahn, Brian (Autor:in) / Olson, Chad (Autor:in) / Scherer, Risa (Autor:in) / Rouhana, Stephen (Autor:in)

    Kongress:

    SAE World Congress & Exhibition ; 2007



    Erscheinungsdatum :

    16.04.2007




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Comparison of the THOR and Hybrid III Lower Extremities in Laboratory Testing

    Olson, C. / Rouhana, S. / Spahn, B. et al. | British Library Conference Proceedings | 2007


    Comparison of the THOR and Hybrid III lower extremities in laboratory testing

    Olson,C. / Ruohana,S. / Spahn,B. et al. | Kraftfahrwesen | 2007


    Response of the Thor-Lx and Hybrid III Lower Extremities in Frontal Sled Tests

    Shaw, Greg / Crandall, Jeff R. / Rudd, Rodney W. | SAE Technical Papers | 2003


    Comparative evaluation of dummy response with Thor-Lx/HIIIr and Hybrid III lower extremities

    Shaw,G. / Rudd,R.W. / Crandall,J.R. et al. | Kraftfahrwesen | 2002


    Response of the Thor-Lx and Hybrid III lower extremities in frontal sled tests

    Rudd,R.W. / Crandall,J.R. / Shaw,G. et al. | Kraftfahrwesen | 2003