This paper demonstrates that linear lumped parameter models of proportional fluid amplifiers are valid until the resonant frequency of the output receiver is approached. The reported experimental results are for variations in the output load resistance only. Variations in power jet pressure and output impedance may change the frequency where the amplifier departs from the predicted response.The experimental procedure and frequency response test results are discussed.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Frequency Response of a Proportional Fluid Amplifier


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Bowman, D. E. (Autor:in) / Strunk, R. D. (Autor:in)

    Kongress:

    National Fuels and Lubricants, Powerplants, Transportation Meetings ; 1967



    Erscheinungsdatum :

    01.02.1967




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch