This method describes the procedure for (1) sampling air in contamination controlled spaces for air-borne particulate contamination 5μ or greater in size and for (2) the microscopic determination of the concentration and size range distribution of the particulate material removed from the air sample (Note 1).
PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF AIR IN DUST CONTROLLED SPACES BY THE PARTICLE COUNT METHOD
01.06.1993
Aufsatz (Konferenz)
Englisch
SAE Technical Papers | 1991