Locati method is suitable in preliminary fatigue tests and production quality control. It is efficient since it uses just one test sample. The method requires that the slope of the S-N curve be known a priori, however. In this paper, a modified Locati method is presented that virtually eliminated this requirement. The method produces a point on the S-N plane that is independent of the slope of the S-N curve. The test design strategy to control the fatigue life of such a point is provided. The presented method has been successfully applied to preliminary fatigue tests of several welded components of ground vehicles.