In a vapor-fed Alkali Metal Thermal to Electric Converter (AMTEC), the sodium in the low pressure condenser (100 Pa) must be returned to the high pressure evaporator (104 to 105 Pa). Most current designs use an EM pump to recirculate the fluid, but a wick-pumped system offers several advantages. A wick-pumped system uses capillary forces to passively return liquid to the evaporator, and to distribute the liquid in the evaporator.In a wick-pumped AMTEC cell, the increase in pressure occurs in the evaporator at the liquid/vapor interface due to surface tension forces. The liquid in the wick has a pressure of a few Pa, and a temperature near the reservoir temperature, so the liquid is superheated by several hundred degrees Celsius. In addition, pressure drops in the liquid return system can drop the liquid sodium pressure below zero, placing the sodium in tension. While sodium can tolerate large superheats before the initiation of nucleate boiling, this superheat may be so high that boiling could occur, blocking the wick with vapor.A capillary pumping demonstrator was fabricated and tested to demonstrate a wick design that can return liquid sodium against the pressure difference between the low pressure condenser and the high pressure evaporator in the AMTEC cell. The demonstrator uses a sodium heat pipe, with a pressure and temperature difference between the evaporator and condenser maintained with a small orifice. The demonstrator successfully operated with the evaporator at 690°C (12,000 Pa), and the condenser at 380°C (40 Pa). The demonstrator was designed to operate with a negative liquid pressure in the liquid return line, and successfully sustained negative pressures (tensions) as low as -2430 Pa.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Sodium Wick Pumping Experiments for a Vapor-Fed AMTEC System


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:

    Kongress:

    27th Intersociety Energy Conversion Engineering Conference (1992) ; 1992



    Erscheinungsdatum :

    03.08.1992




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Conical Evaporator and Liquid Return Wick Model for Vapor Anode, Multi-Tube AMTEC Cells

    Tournier, J.-M. / El-Genk, M. S. / University of New Mexico | British Library Conference Proceedings | 2000


    Conical evaporator and liquid-return wick model for vapor anode, multi-tube AMTEC cells

    Tournier, Jean-Michel / El-Genk, Mohamed S. | American Institute of Physics | 2000


    Experimental Study on AMTEC Using Sodium-Vapor-Fed Cells

    Yamada, A. / Tsukuda, H. / Hashimoto, T. et al. | British Library Conference Proceedings | 1994


    Performance of a wick return AMTEC cell with a micromachined condenser

    Crowley, Christopher / Izenson, Michael / Wallis, Peter et al. | AIAA | 1994


    Performance of a Wick Return AMTEC Cell with a Micromachined Condenser

    Crowley, C. / Izenson, M. / Wallis, P. et al. | British Library Conference Proceedings | 1994