This paper presents the study of refrigerant charge imbalance between A/C (cooling) mode and HP (heating) mode of a mobile reversible system. Sensitivities of cooling and heating capacity and energy efficiency with respect to refrigerant charge were investigated. Optimum refrigerant charge level for A/C mode was found to be larger than that for HP mode, primarily due to larger condenser size in A/C mode. Refrigerant charge retention in components at both modes were measured in the lab by quick close valve method. Modeling of charge retention in heat exchangers was compared to experimental measurements. Effect of charge imbalance on oil circulation was also discussed.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Feng, Lili (Autor:in) / Hrnjak, Predrag (Autor:in)

    Kongress:

    WCX™ 17: SAE World Congress Experience ; 2017



    Erscheinungsdatum :

    28.03.2017




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System

    Feng, Lili / Hrnjak, Predrag | British Library Conference Proceedings | 2017



    Heat-pump system with refrigerant charge diagnostics

    ALSALEEM FADI M / HEMMELGARN GREGG M | Europäisches Patentamt | 2017

    Freier Zugriff

    Refrigerant circuit for a vehicle air conditioning system with heat pump

    GRAAF MARC / RICHTER GERALD | Europäisches Patentamt | 2019

    Freier Zugriff