Nowadays, it becomes more important to predict the heat transport capability of axial grooved wick heat pipes with asymmetrical heating accurately. The authors succeeded in calculation by applying transient analysis. It was found that the heat transport limit is the point where all the grooves began to have dry out region.The prediction of the heat pipe agreed well with the test data with asymmetrical heating under micro-gravity as well as under normal gravity. In addition, it also showed there is no marked difference between symmetrical heating and asymmetrical heating to extent of tested heat pipe design.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Heat Transport Capability of Axial Grooved Wick Heat Pipes with Asymmetrical Heating


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Yao, Akira (Autor:in) / Nomura, Takehide (Autor:in) / Ogushi, Testsurou (Autor:in)

    Kongress:

    International Conference On Environmental Systems ; 1997



    Erscheinungsdatum :

    01.07.1997




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch


    Schlagwörter :


    Heat Transport Capability of Axial Grooved Wick Heat Pipes with Asymmetrical Heating

    Nomura, T. / Yao, A. / Ogushi, T. et al. | British Library Conference Proceedings | 1997



    Heat pipe with axial wick

    AMBROSE JAY H / HOLMES ROLLAND | Europäisches Patentamt | 2020

    Freier Zugriff

    Heat pipe with axial wick

    AMBROSE JAY H / HOLMES ROLLAND | Europäisches Patentamt | 2023

    Freier Zugriff

    Axially grooved crossing heat pipes

    WU GORDON | Europäisches Patentamt | 2016

    Freier Zugriff