Boiling of the coolant in an engine, by design or by circumstance, is limited by the critical heat flux phenomenon. As a first step in providing relevant engine design information, this study experimentally addressed both rate of boiling heat transfer and conditions at the critical point of water in a horizontal tube of 2.98-mm inside diameter and 0.9144-m heated length. Experiments were performed at a system pressure of 203 kPa, mass fluxes of 50-200 kg/m2s, and inlet temperatures from ambient to 80°C. Experimental results and comparisons with predictive correlations are presented.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Critical Heat Flux and Boiling Heat Transfer to Water in a 3-mm-Diameter Horizontal Tube


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    France, David M. (Autor:in) / Hull, John R. (Autor:in) / Wambsganss, Martin W. (Autor:in) / Yu, Wenhua (Autor:in)

    Kongress:

    Vehicle Thermal Management Systems Conference & Exposition ; 2001



    Erscheinungsdatum :

    2001-05-14




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Critical heat flux and boiling heat transfer to water in a 3-mm-diameter horizontal tube

    Yu,W. / Wambsganss,W. / Hull,J.R. et al. | Kraftfahrwesen | 2001


    2001-01-1768 Critical Heat Flux and Boiling Heat Transfer to Water in a 3-mm-Diameter Horizontal Tube

    Yu, W. / Wambsganss, M. W. / Hull, J. R. et al. | British Library Conference Proceedings | 2001