The faulty performance of two level three phase voltage inverter is studied under open-switch conditions. This inverter is three phase two level six IGBT voltage source inverter feeding a three phase balanced resistive-inductive load. The inverter three phases currents zero harmonic components are used as diagnostic indices. A knowledge algorithm is based to get information on which IGBT is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switch. Presented simulation results confirm the effectiveness of the proposed methodology.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Analysis of Open-Switch Fault Two Level Three Phase Voltage Inverter Behaviour and Automatic Detection and Location Using Zero Harmonic Component


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Benslimane, T. (Autor:in)

    Kongress:

    SAE World Congress & Exhibition ; 2007



    Erscheinungsdatum :

    16.04.2007




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch