This paper presents the influence of parameters such as the steepness of voltage, the electrode configuration, the spacing of the diverter strips, the length of the diverter strips and the aging effect of the insulating panel for the protection effectiveness of segmented diverter strips (button strips) and solid diverter strips which are normally used as lightning protection system of aircraft radomes and fairings. Differences of the protection effectiveness between segmented and solid diverter strips and between the different types of segmented diverter strips are described. Derived from these results proposals are given in order to improve the current testing procedure for aircraft radomes as defined in the AE4L report [1]. Especially the use of at least one additional slow fronted waveform is necessary.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Investigation into the Protection Effectiveness of Segmented Diverter Strips (Button Strips) and Solid Diverter Strips


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:

    Kongress:

    International Conference on Lightning and Static Electricity ; 1999



    Erscheinungsdatum :

    1999-06-22




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Flashover Voltage Characteristics of Segmented Diverter Strips

    Drumm, Frank | SAE Technical Papers | 1999


    SEGMENTED LIGHTNING DIVERTER ELEMENT HAVING INTEGRATED ESD PROTECTION

    WEBER LUTZ / KASTE MICHAEL / KEBEL ROBERT et al. | Europäisches Patentamt | 2018

    Freier Zugriff

    Segmented lightning diverter element having integrated ESD protection

    WEBER LUTZ / KASTE MICHAEL / KEBEL ROBERT et al. | Europäisches Patentamt | 2020

    Freier Zugriff

    Electronic strips

    Domogala, Philippe | Online Contents | 2009


    Effectiveness of Rumble Strips on Freeways

    Yang, Yang / Sun, Xiaoduan / He, Yulong | ASCE | 2010