The International Space Station (ISS) redesign made operational and interface requirements changes to the previous Space Station Freedom baseline. These changes include Oxygen Generation Assembly (OGA) production only on the daylight side of each orbit; nitrogen interface pressure reduction to 100 +/- 10 psia (690 +/- 69 kPa); and available production rates of nominal, nominal +10%, and nominal -10%.In 1994 a test program was initiated at MSFC to verify OGA capabilities for cyclic operation. The liquid feed solid polymer electrolyzer from the 1990 OGA Comparative Test was refurbished and modified as required. This paper describes the operation of the test unit, and presents a discussion of the test data and test results.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Solid Polymer Electrolysis Oxygen Generator Testing at MSFC


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:

    Kongress:

    International Conference On Environmental Systems ; 1996



    Erscheinungsdatum :

    01.07.1996




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Solid Polymer Electrolyte Oxygen Generator Assembly Life Testing at MSFC - The First Year

    Erickson, R. J. / Roy, R. J. / Mason, R. K. et al. | British Library Conference Proceedings | 1997


    Solid Polymer Electrolyte Oxygen Generator Assembly Life Testing at MSFC - The First Year

    Mason, Richard K. / Erickson, Robert J. / Roy, Robert J. | SAE Technical Papers | 1997




    Analysis Supporting MSFC Cryostat Testing Unit

    Foster, Winfred A., Jr. / Jenkins, Rhonald M. | NTRS | 1997