A new method for estimating the value of the load factor (the ratio of the additional bolt force to the load) is proposed by introducing the spring constant kpt . The value of kpt is analyzed by using an axisymmetric theory of elasticity. For verification of the proposed method, experiments were carried out to measure the load factor. A fairly good agreement is seen between the analytical and the experimental results. The effects of some factors on the load factor were discussed.
New Design Formula for Bolted Joints under Tensile Loads
Sae Technical Papers
SAE 2006 World Congress & Exhibition ; 2006
2006-04-03
Aufsatz (Konferenz)
Englisch
New design formula for bolted joints under tensile loads
Kraftfahrwesen | 2006
|Bolted Joints - Design and Control
SAE Technical Papers | 1986
|Bolted joints - design and control.
Kraftfahrwesen | 1986
|