Carrier Injection Sensorless (CIS) rotor position estimation for electric machines depends on the rotor saliency “seen” from the stator terminals. Compared to permanent magnet and induction machines, wound field synchronous machine rotor saliency characteristics are more complex. At typical carrier frequencies subtransient characteristics dominate. Injecting positively rotating carrier voltages at the stator terminals of a machine having rotor saliency produces both positively and negatively rotating carrier currents. The impedances relating currents to injected carrier voltages are derived from the dq reference frame synchronous machine model. Analytical results are compared to simulation and limited test results for an aircraft starter/generator.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Carrier Injection Positive and Negative Sequence Impedances for Wound Field Synchronous Starter/Generators


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:

    Kongress:

    Power Systems Conference ; 2004



    Erscheinungsdatum :

    02.11.2004




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Carrier Injection Positive and Negative Sequence Impedances for Wound Field Synchronous Starter/Generators

    Markunas, A. L. / Society of Automotive Engineers | British Library Conference Proceedings | 2004


    Starter-Generators

    Online Contents | 1994


    Integrated starter generators

    Kimberley,W. / Visteon,GB | Kraftfahrwesen | 2003


    Alternating current starter generators

    BURNS, D.O. | Emerald Group Publishing | 1973