An experimental and theoretical investigation of a flame/wall interface is presented to help understand the phenomenon of one-wall quenching. Special slot burners were designed to permit high spatial resolution, laser probing of the flame/wall interface, often referred to as the wall quench zone. Laser Raman spectroscopy and veiocimetry measurements of the fuel, temperature, and velocity in the flame/wall interface region show that the fuel is consumed rapidly (<5 ms) in spite of the low (~ 1000 K) temperature. Flame ionization detector measurememts ments confirm the absence of exhaust hydrocarbon from these premixed, laminar flames. Measurements of OH near the wall, taken together with a theoretical study of combusting flows for the burner geometry, identify species diffusion of fuel and radicals as the important process in the fuel decay. Relative flame-wall motion was shown to have only a weak influence on the results. These conclusions suggest that one-wall quenching in homogeneous change, S.I. engines is not a likely source for exhaust hydrocarbons.
Hydrocarbon Combustion near a Cooled Wall
Sae Technical Papers
SAE International Congress and Exposition ; 1982
01.02.1982
Aufsatz (Konferenz)
Englisch
Hydrocarbon Combustion near a Cooled Wall
Kraftfahrwesen | 1982
|Near Wall Measurements Along a Film Cooled Wall
AIAA | 2006
|Near Wall Measurements Along a Film Cooled Wall
British Library Conference Proceedings | 2006
|Near-Wall Subgrid Mixing Model for Film-Cooled Surfaces
AIAA | 2019
|Analysis of Unburned Hydrocarbon Generated from Wall under Lean Combustion
SAE Technical Papers | 2020
|