The SAE Large Male and Small Female Dummy Task Group has recommended a change to the Hybrid III dummy hip joint. This change was made because of a non-biofidelic interference in the current design that can influence chest accelerations. The modifications include a new femur casting shaft design and the addition of an elastomeric stop to the top of the casting. Static testing and Hyge sled tests were done to evaluate the modifications. Based on the results, the new design satisfied the requirements set by the SAE task group and reduced the influence of hip joint characteristics on chest accelerations.
An Evaluation of the SAE Recommended Design Changes to the Hybrid III Dummy Hip Joint
Sae Technical Papers
International Congress & Exposition ; 1995
1995-02-01
Aufsatz (Konferenz)
Englisch
An Evaluation of the SAE Recommended Design Changes to the Hybrid III Dummy Hip Joint
British Library Conference Proceedings | 1995
|An evaluation of the SAE recommended design changes to the Hybrid III dummy hip joint
Kraftfahrwesen | 1995
|Evaluations of the Recommended New Parts for the Hybrid III Dummy - Neck Shield and Hip Joint
SAE Technical Papers | 1996
|Evaluations of the recommended new parts for the Hybrid III dummy - neck shield and hip joint
Kraftfahrwesen | 1996
|SAE Technical Papers | 2005
|