The test rig was designed and built to determine whether it is possible to objectively measure the effect of coolant composition on the performance of engine coolant pump seals. The rig uses a standard, current production, mechanical seal. A low silicate U.S. made coolant for baseline tests was selected. The effect of increased total dissolved solids (TDS) will be determined by adding twice and four times the normal recommended level (3% by volume) of supplemental coolant additive (SCA). Shakedown tests with the low silicate coolant were successfully completed. Leakage and wear characteristics observed on the baseline tests were used as a reference to evaluate seal performance in coolants containing SCA.
Development of Test Stand to Measure the Effect of Coolant Composition on Engine Coolant Pump Seal Leakage
Sae Technical Papers
International Congress & Exposition ; 1990
01.02.1990
Aufsatz (Konferenz)
Englisch
SAE | 1978
SAE | 1984
SAE | 2000
SAE | 2002