This paper presents an experimental study of lubricant effect on the performance of microchannel evaporators in a typical MAC system. R134a is used as the refrigerant with PAG46 lubricant. The increase of oil circulation rate elevates the pressure drop of the evaporator. The specific enthalpy change in evaporator decreases with increasing oil circulation rate, while refrigerant distribution appears to be more uniform as indicated by infrared images of the evaporator surface temperatures. Thus mass flow rate increases.


    Zugriff

    Zugriff prüfen

    Verfügbarkeit in meiner Bibliothek prüfen

    Bestellung bei Subito €


    Exportieren, teilen und zitieren



    Titel :

    Lubricant Effect on Performance of R134a MAC Microchannel Evaporators


    Weitere Titelangaben:

    Sae Technical Papers


    Beteiligte:
    Li, Huize (Autor:in) / Hrnjak, Predrag (Autor:in)

    Kongress:

    SAE 2014 World Congress & Exhibition ; 2014



    Erscheinungsdatum :

    01.04.2014




    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Print


    Sprache :

    Englisch




    Lubricant Effect on Performance of R134a MAC Microchannel Evaporators

    Li, H. / Hrnjak, P. / Society of Automotive Engineers | British Library Conference Proceedings | 2014


    Lubricant Impact on R134a Distribution and Microchannel Heat Exchanger Performance

    Zou, Y. / Li, H. / Hrnjak, P. et al. | British Library Conference Proceedings | 2014


    Lubricant Impact on R134a Distribution and Microchannel Heat Exchanger Performance

    Li, Huize / Hrnjak, Predrag / Zou, Yang | SAE Technical Papers | 2014


    Effect of Flash Gas Bypass on the Performance of R134a Mobile Air-Conditioning System with Microchannel Evaporator

    Bielskus, Algirdas / Tuo, Hanfei / Hrnjak, Pega | SAE Technical Papers | 2011