In this study, the lowest loss point is calculated using the permeance method when the machine parameters of the interior permanent magnet synchronous motor are changed. Using the proposed method, the motor loss is easily calculated compared to the conventional method. The periodic change in the magnetic resistance in the air‐gap according to the rotation of the rotor does not need to be considered because the magnetic equivalent circuits of the rotor and stator are separated. In this study, the motor loss is calculated by the proposed method and a finite element method (FEM). As a result, the error in the calculation results between the permeance method and the FEM is 2.9%. On the other hand, the motor losses are calculated by the permeance method when some machine parameters are changed. As a result, these results agree in principle with those of the FEM. Therefore, the validity of the proposed method is confirmed. In addition, the method for motor design is considered in terms of the loss.
Loss Minimization Design Using Permeance Method for Interior Permanent Magnet Synchronous Motor
Electrical engineering in Japan ; 199 , 4 ; 33-43
2017
Aufsatz (Zeitschrift)
Englisch
Method for controlling interior permanent magnet synchronous motor
Europäisches Patentamt | 2018
Model-Based Minimum Total Loss Control of Interior Permanent Magnet Synchronous Motor
British Library Online Contents | 2016
|Performance of a double-layered interior permanent magnet synchronous motor
British Library Conference Proceedings | 1996
|