The NASA Energy Efficient Transport (EET) airfoil was tested at NASA Langley's Low- Turbulence Pressure Tunnel (LTPT) to assess the effectiveness of distributed Active Flow Control (AFC) concepts on a high-lift system at flight scale Reynolds numbers for a medium-sized transport. The test results indicate presence of strong Reynolds number effects on the high-lift system with the AFC operational, implying the importance of flight-scale testing for implementation of such systems during design of future flight vehicles with AFC. This paper describes the wind tunnel test results obtained at the LTPT for the EET high-lift system for various AFC concepts examined on this airfoil.
Active Control of Flow Separation on a High-Lift System with Slotted Flap at High Reynolds Number
25th AIAA Applied Aerodynamics Conference ; 2007 ; Miami, FL, United States
25.06.2007
Aufsatz (Konferenz)
Keine Angabe
Englisch
Active Control of Flow Separation on a High-Lift System with Slotted Flap at High Reynolds Number
British Library Conference Proceedings | 2007
|High Reynolds Number Simulation of Distributed Active Flow Control for a High-Lift System
British Library Conference Proceedings | 2007
|