The Battery Orbital Replacement Unit (ORU) was designed to meet the following requirements: a 6.5-year design life, 38,000 charge/discharge Low Earth Orbit cycles, 81-Amp-hr nameplate capacity, 4 kWh nominal storage capacity, contingency orbit capability, an operating temperature of 5 +/- 5 C standard orbit and 5+5/-10 C contingency orbit, a non-operating temperature of -25 to +30 C, a five-year Mean Time between failure, an on-orbit replacement using ISS robotic interface, and one launch to orbit and one return to ground. The ISS electrical power system is successfully maintaining power for all on-board loads. ISS Eclipse power is currently supplied by six Ni-H2 batteries (12 ORUs), which are operating nominally.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    International Space Station Nickel-Hydrogen Battery Startup and Initial Performance


    Beteiligte:
    Dalton, Penni (Autor:in) / Cohen, Fred (Autor:in) / Hajela, Gyan (Autor:in)


    Erscheinungsdatum :

    01.02.2002


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch






    Space Station Nickel-Hydrogen Battery ORU Test

    Dalton, P. / Cohen, F. / American Institute of Aeronautics and Astronautics | British Library Conference Proceedings | 1994


    Space Station nickel-hydrogen battery ORU test

    Cohen, Fred / Dalton, Penni | AIAA | 1994


    International Space Station nickel-hydrogen battery cell testing at NAVSURFWARCENDIV Crane

    Moore, B.A. / Brown, H.M. / Miller, T.B. | Tema Archiv | 1997