Iodinated resin bed for disinfecting water regenerated to extend its useful life. Water flows through regeneration bed of crystalline iodine during regeneration. At other times, flow diverted around regeneration bed. Although regeneration cycle was manually controlled in demonstration, readily automated to start and stop according to signals and stop according to signals from concentration sensors. Further benefit of regeneration is that regeneration bed provides highly concentrated biocide source (200 mg/L) when needed. Concentrated biocide used to superiodinate system after contamination from routine maintenance or unexpected introduction of large concentration of microbes.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Regenerable Iodine Water-Disinfection System


    Beteiligte:

    Erschienen in:

    Erscheinungsdatum :

    1994-07-01



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :




    Regenerable Iodine Water-Disinfection System

    Sauer, Richard L. / Colombo, Gerald V. / Jolly, Clifford D. | NTRS | 1994


    Recent Experiences with Iodine Water Disinfection in Shuttle

    Flanagan, David T. / Schultz, John R. / Gibbons, Randall E. et al. | SAE Technical Papers | 1990


    Effects of Iodine Disinfection Products in Spacecraft Water

    Janik, Daniel S. / Sauer, Richard L. / Thorstenson, Yvonne R. | SAE Technical Papers | 1987