The Hubble Space Telescope (HST) nickel-hydrogen battery module was designed by Lockheed Missile & Space Co (LMSC) and manufactured by Eagle-Picher Ind. (EPI) for the Marshall Space Flight Center (MSFC) as an Orbital Replacement Unit (ORU) for the nickel-cadmium batteries originally selected for this low earth orbit mission. The design features of the HST nickel hydrogen battery are described and the results of an extended charge retention test are summarized.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Charge retention test experiences on Hubble Space Telescope nickel-hydrogen battery cells


    Beteiligte:
    Nawrocki, Dave E. (Autor:in) / Driscoll, J. R. (Autor:in) / Armantrout, J. D. (Autor:in) / Baker, R. C. (Autor:in) / Wajsgras, H. (Autor:in)


    Erscheinungsdatum :

    01.02.1993


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Nickel-hydrogen battery testing for Hubble Space Telescope

    Baggett, R.M. / Whitt, T.H. | Tema Archiv | 1989


    Hubble Space Telescope Nickel-Hydrogen Battery Testing - An Update

    Whitt, T. H. / Brewer, J. C. / NASA Aerospace Flight Battery Systems Program | British Library Conference Proceedings | 1995


    Hubble Space Telescope six-battery nickel-cadmium mission simulation test

    Jackson, L.G. / Bush, J.R. jun. / Lanier, J.R. jun. | Tema Archiv | 1989


    Hubble Space Telescope Nickel-Hydrogen Battery and Cell Testing - An Update

    Brewer, Jeffrey C. / Whitt, Thomas H. | SAE Technical Papers | 1992


    Voltage and capacity stability of the Hubble telescope nickel-hydrogen battery

    Vaidyanathan, H. / Wajsgras, H. / Rao, G.M. | Tema Archiv | 1996