Spools rotated to pull thermocouple wires through liquid nitrogen, while output voltage of thermocouple recorded on strip chart. Wires exposed to severe temperature gradients, amounting to overall change of 200 degrees C, where they enter and leave liquid nitrogen. If wires homogeneous, net output voltage zero. If inhomogeneity passes through liquid-nitrogen/air interface, resulting deviation of output voltage from zero seen immediately on strip chart. If inhomogeneity greater than allowable, reels stopped temporarily so inhomogeneity tagged before wound onto takeup reel.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Measuring Inhomogeneities In Thermocouple Wires


    Beteiligte:

    Erschienen in:

    Erscheinungsdatum :

    01.08.1993



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Welding Wires To Thin Thermocouple Films

    Holanda, Raymond / Kim, Walter S. / Danzey, Gerald A. et al. | NTRS | 1993




    Thermocouple Installation

    W. B. Powell / L. R. Potter / K. S. Macdavid | NTIS | 1974


    An innovative flow-measuring device - Thermocouple boundary layer rake