A new method is described for assessing the consistency of structural modal parameters identified with the Eigensystem Realization Algorithm. Identification results show varying consistency in practice due to many sources including high modal density, nonlinearity, and inadequate excitation. Consistency is considered to be a reliable indicator of accuracy. The new method is the culmination of many years of experience in developing a practical implementation of the Eigensystem Realization Algorithm. The effectiveness of the method is illustrated using data from NASA Langley's Controls-Structures-Interaction Evolutionary Model.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    A consistent-mode indicator for the eigensystem realization algorithm


    Beteiligte:
    Pappa, R. S. (Autor:in) / Elliott, K. B. (Autor:in) / Schenk, A. (Autor:in)

    Kongress:

    AIAA Dynamics Specialists Conference ; 1992 ; Dallas, TX, United States


    Erscheinungsdatum :

    1992-01-01


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :



    Consistent-mode indicator for the eigensystem realization algorithm

    Pappa, Richard S. / Elliott, Kenny B. / Schenk, Axel | NTRS | 1993


    Consistent-mode indicator for the eigensystem realization algorithm

    PAPPA, RICHARD S. / ELLIOTT, KENNY B. / SCHENK, AXEL | AIAA | 1993


    A consistent-mode indicator for the eigensystem realization algorithm

    PAPPA, R. / ELLIOTT, K. / SCHENK, A. | AIAA | 1992


    An improved mode accuracy indicator for Eigensystem Realization Analysis (ERA) techniques