Johnson Controls, Inc. has developed a multiple cell CPV nickel hydrogen battery that offers significant weight, volume, and cost advantages for aerospace applications. The baseline design was successfully demonstrated through the testing of a 26-cell prototype, which completed over 7000 44 percent depth-of-discharge low earth orbit cycles. Prototype designs using both nominal 5 and 10 inch diameter vessels are currently being developed for a variety of customers and applications.
Multiple cell CPV nickel-hydrogen battery
01.05.1991
Aufsatz (Konferenz)
Keine Angabe
Englisch
Multiple Cell CPV Nickel Hydrogen Battery
SAE Technical Papers | 1991
|SAFT Nickel Hydrogen Cell and Battery Update
NTRS | 1997
|Nickel Hydrogen Battery Cell Storage Matrix Test
SAE Technical Papers | 1992
|SAFT Nickel Hydrogen Cell and Battery Update
British Library Conference Proceedings | 1997
|Nickel hydrogen battery cell storage matrix test
NTRS | 1993
|