A study was made of the High Temperature Design Codes ASME N47, British R5, and the French RCC-MR Rules. It is concluded that all these codes provide a good basis of design for space application. The new British R5 is the most complete since it deals with the problem of defects. The ASME N47 was subjected longer to practical application and scrutiny. A draft code is introduced, and a proposed draft for high temperature design in which attempts were made to identify gaps and improvements is suggested. The design is limited by creep characteristics. In these circumstances, life is strongly affected by the selected value of the factor of safety. The factor of safety of primary loads adopted in the codes is 1.5. Maybe a lower value of 1.25 is permissible for use in space. Long term creep rupture data for HAYNES 188 is deficient and it is suggested that extrapolation methods be investigated.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Long term integrity for space station power systems


    Beteiligte:
    Leckie, F. A. (Autor:in) / Marriott, D. L. (Autor:in)

    Erscheinungsdatum :

    01.01.1991


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Going for the long term (space station power plant)

    Lollar, L.F. / Weeks, D.J. | Tema Archiv | 1987



    Planning for long term control of Space Station

    Buchanan, H. / Seltzer, S. M. | NTRS | 1983