New type of capillary-pumped heat-transfer loop primes itself at startup. Removes substantial quantities of heat like that generated by people and equipment in rooms and vehicles. Creates continuous path for its working fluid; both vapor and liquid move in same direction. Key element in operation of loop is formation of slugs of liquid, condensed from vapor and moved along loop by vapor bubbles before and after it. Both evaporator and condenser contain axial arteries carrying water. Heat entering evaporator from heat source provides energy for transport of fluid and heat. Dimensions in inches.
Capillary-Pumped Heat-Transfer Loop
NASA Tech Briefs ; 13 , 9
1989-09-01
Sonstige
Keine Angabe
Englisch
Capillary-Condenser-Pumped Heat-Transfer Loop
NTRS | 1989
|NTRS | 1990
|The Hybrid Capillary Pumped Loop
SAE Technical Papers | 1988
|Capillary Pumped Loop Application Guide
SAE Technical Papers | 1993
|