Water leakage in heat exchanger measured directly with help of electroytic hygrometer. In new technique, flow of nitrogen gas set up in one loop of heat exchanger. Other loop filled with water under pressure. Water concentration produced by leakage of water into nitrogen flow measured by hygrometer. New measurement method determines water concentrations up to 2,000 parts per million with accuracy of +/- 5 percent.
Measuring Heat-Exchanger Water Leakage
NASA Tech Briefs ; 10 , 1
01.06.1986