Hydrogen-absorption refrigerating system provides about 650 mW of cooling at 20 to 29 K in continuous, closed-cycle operation. Three thermally cycled absorbers/desorbers act as compressors. System successfully tested below 29 K for over 1,000 h, while separate room-temperature hydride compressor operated continuously for 6,000 h. Due to lack of moving parts, lifetimes of 10 years or more eventually expected.
LaNi5 Hydrogen-Absorption Cryogenic System
NASA Tech Briefs ; 9 , 3
01.01.1986