The Space Shuttle STS-3 mission carried a Plasma Diagnostics Package (PDP) whose instrumentation included an S-band antenna and detector. The PDP was maneuvered by the Remote Manipulator System arm through a computer controlled sequence in the Orbiter's X-Z plane, above the quad and hemi S-band communications antennas. Antenna field strength measurements were conducted during transmitter high power modes, and the results were compared to ground full scale measurements and predictions. A field strength 4.8 + or - 3 dB higher than predicted is noted. This RF field is primarily due to the quad PM transmitter, whose power output of 115 W compares with 15 W for the hemi.
Radio frequency fields generated by the S-band communication link on OV102
1984-08-01
Sonstige
Keine Angabe
Englisch
British Library Conference Proceedings | 1994
|