A reverse flow combustor liner constructed of Lamilloy (a multilaminate transpiration type material) is compared both analytically and experimentally with a conventional splash film-cooled design with the same combustor configuration. Comparison of selected critical combustor panels indicated that it was possible to maintain the liner temperature similar between the two configurations using 50 percent less coolant for the Lamilloy as compared with the reference film-cooled combustor. Additional benefits indicated improvement in outlet temperature distribution and NOx emission level.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Small gas turbine combustor study - Combustor liner evaluation


    Beteiligte:

    Kongress:

    American Institute of Aeronautics and Astronautics, Aerospace Sciences Meeting ; 1983 ; Reno, NV


    Erscheinungsdatum :

    01.01.1983


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch




    Small gas turbine combustor study: Combustor liner evaluation

    Norgren, C. T. / Riddlebaugh, S. M. | NTRS | 1983


    Small Gas Turbine Combustor Study: Combustor Liner Evaluation

    C. T. Norgren / S. M. Riddlebaugh | NTIS | 1983


    Small gas turbine combustor study - Combustor liner evaluation

    NORGREN, C. / RIDDLEBAUGH, S. | AIAA | 1983



    Combustor liner support assembly

    Halila, Ely E. | NTRS | 1994