The model building, development, and testing experience gained during 8 years of operation of the 0.3-m Transonic Cryogenic Tunnel (TCT) is summarized. The summary is divided into four portions: (1) models tested in the 0.3-m TCT's original octagonal test section; (2) models tested in the present two dimensional test section; (3) models tested as a part of tunnel calibration and the development of advanced technology airfoils; and (4) development of a new way to construct two dimensional airfoil models. Design requirements imposed on the models by high Reynolds number testing at cryogenic temperatures are reviewed.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Model experience in the Langley 0.3-m transonic cryogenic tunnel


    Beteiligte:
    Lawing, P. L. (Autor:in) / Kilgore, R. A. (Autor:in)


    Erscheinungsdatum :

    01.09.1981


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Image degradation in Langley 0.3-meter transonic cryogenic tunnel

    Snow, W. L. / Burner, A. W. / Goad, W. K. | NTRS | 1982


    Image Degradation in Langley 0.3-Meter Transonic Cryogenic Tunnel

    W. L. Snow / A. W. Burner / W. K. Goad | NTIS | 1982


    Langley annular transonic tunnel

    Habel, L.W. / Henderson, J. / Miller, M.F. | Engineering Index Backfile | 1952


    The Langley Annular Transonic Tunnel

    Habel, Louis W / Henderson, James H / Miller, Mason F | NTRS | 1952