Laboratory tests indicate electron magnetic resonance (EMR) would be effective in measuring thickness of coal overlying rock substrate. In prototype dual-frequency EMR system, Sample is irradiated by two radio frequencies. Signals are mixed, producing sum and difference output frequencies that are detected by receiver. Magnetic field is varied to scan resonant spot through sample. In system designed for field use, electromagnet is U-shaped, so that sample can be adjacent to, rather than inside the probe. Same coil is used for transmitting and receiving.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    EMR Gage Would Measure Coal Thickness Accurately


    Beteiligte:
    King, J. D. (Autor:in) / Rollwitz, W. L. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    01.11.1982



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Water-Thickness Gage

    Weinstein, L. M. | NTRS | 1986


    Ultrasonic Paint Thickness Gage

    Salman, S. / Sprinkle, T. / American Iron and Steel Institute et al. | British Library Conference Proceedings | 1996



    The narrow gage, especially one-meter gage

    Engineering Index Backfile | 1925


    Pick the right parameters to measure LEDs accurately

    Distl, R. / Nagele, T. | British Library Online Contents | 1999