The structural thermal test of an advanced ramjet missile section required strain measurements as high as 922 K (1200 F). Since there is relatively little experience in the use of strain gages above the 700-755 K (800-900 F) level, a program was initiated to select and evaluate the best available gage. Candidate gages suitable for measurements up to 922 K (1200 F) were selected. This involved the determination of their operating characteristics, availability, cost, installation aspects, etc. The evaluation involved the following tests: strain as a function of load at room temperature and apparent strain as a function of temperature.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    High temperature strain gage evaluation


    Beteiligte:


    Erscheinungsdatum :

    01.01.1977


    Medientyp :

    Aufsatz (Konferenz)


    Format :

    Keine Angabe


    Sprache :

    Englisch




    PdCr based high temperature static strain gage

    LEI, JIH-FEN / WILLIAMS, W. | AIAA | 1990


    High Temperature Strain Measurement with a Resistance Strain Gage

    Lei, J.-F. / Fichtel, E. / McDaniel, A. et al. | British Library Conference Proceedings | 1993


    High Temperature Strain Measurement with a Resistance Strain Gage

    Lei, J.-F. / Fichtel, E. / McDaniel, A. et al. | British Library Conference Proceedings | 1993


    Strain Gage

    NTIS | 1995


    Development of a Temperature Compensated High-Temperature Strain Gage

    Moore, T. C. / Society of Experimental Mechanics | British Library Conference Proceedings | 1993