A test was conducted to evaluate the fire containment characteristics of a Boeing 747 lavatory module. Results showed that the fire was contained within the lavatory during the 30-minute test period with the door closed. The resistance of the lavatory wall and ceiling panels and general lavatory construction to burn-through under the test conditions was demonstrated.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Development of aircraft lavatory compartments with improved fire resistance characteristics, phase 1: Fire containment test of a wide body aircraft lavatory module


    Beteiligte:
    Anderson, R. A. (Autor:in) / Arnold, D. B. (Autor:in) / Johnson, G. A. (Autor:in) / Tustin, E. A. (Autor:in)

    Erscheinungsdatum :

    01.07.1978


    Medientyp :

    Report


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :




    Fire safety evaluation of aircraft lavatory and cargo compartments

    Kourtides, D. A. / Parker, J. A. / Hilado, C. J. et al. | NTRS | 1976


    Fire safety evaluation of aircraft lavatory and cargo compartments

    Kourtides, D. A. / Parker, J. A. / Hilado, C. J. et al. | NTRS | 1975


    Fire Safety Evaluation of Aircraft Lavatory and Cargo Compartments