Samples are heated by electron bombardment in high-temperature calorimeter that operates from 1,000 to 3,600 C yet consumes less that 100 watts at temperatures less than 2,500 C. Contamination of samples is kept to minimum by suspending them from wire in vacuum chamber. Various sample slopes such as wires, dishs, spheres, rods, or irregular bodies can be accommodated and only about 100 nq of samples are needed for accurate measurements.


    Zugriff

    Zugriff über TIB

    Verfügbarkeit in meiner Bibliothek prüfen


    Exportieren, teilen und zitieren



    Titel :

    Containerless high-temperature calorimeter


    Beteiligte:
    Lacy, L. L. (Autor:in) / Nisen, D. B. (Autor:in) / Robinson, M. B. (Autor:in)

    Erschienen in:

    Erscheinungsdatum :

    1979-08-01



    Medientyp :

    Sonstige


    Format :

    Keine Angabe


    Sprache :

    Englisch


    Schlagwörter :


    Modular Containerless Processing Facility

    Morrison, Andrew D. | NTRS | 1990


    Containerless-Processing Module

    Wang, T. G. / Barmatz, M. B. / Chamberlain, F. R. et al. | NTRS | 1984


    Comments on Containerless Processing.

    Reynolds, Joseph M. / Hazelrigg, George A. | AIAA | 1986


    Levitator for Containerless Processing

    Berg, L. H. / Oran, W. A. / Theiss, J. M. | NTRS | 1982


    Containerless processing of tungsten

    Beser, N. / Frost, R. T. / Okress, E. C. et al. | NTRS | 1977